Product Code: TPDCR125P
Availability: Next Day Special Order
The DRM-125-3P is an MID approved 6 module wide, DIN Rail mountable electricity meter from Crompton Instruments. It is rated at 125 Amps, direct connected and packed with additional features.
As standard, it is an Import & Export meter with both registers available for Dual Rate reading. The back lit LCD display presents Import & Export Active Energy (kWh) accurate to class 1 (1%) and Reactive Energy (kVArh) to class 2 (2%).
The DRM-125-3P is an MID approved 6 module wide, DIN Rail mountable electricity meter from Crompton Instruments. It is rated at 125 Amps, direct connected and packed with additional features.
As standard, it is an Import & Export meter with both registers available for Dual Rate reading. The back lit LCD display presents Import & Export Active Energy (kWh) accurate to class 1 (1%) and Reactive Energy (kVArh) to class 2 (2%).
The power bar indicates, in 10% increments, the fraction of maximum demand at all times. The display also indicates whether the Reactive Energy is inductive or capacitive.
This meter comes with terminals for a pulsed output for kWh, a pulsed output for kVArh and for a tariff change command. Additional communication is available through a one module wide communications module which is read through an infrared port available on the meter. Options are: M-Bus, Modbus-RTU RS485, SD card data logger and a power supply transformer for data loggers.
N.B. This meter can be fitted into a DIN Rail enclosure. Click here to see our full range of Enclosures.
Meter Type | Three Phase | ||
Fitting Type | DIN Rail | ||
Max Current (amps) | 125 | ||
MID Approved | Yes | ||
Smart | No | ||
Input Type | Direct Connect | ||
Output Type | Pulse (optional comms modules available) | ||
Tariffs | Dual | ||
Import / Export | Import & Export | ||
Module Width | 6 | ||
Availability | Next Day | ||
Condition | New | ||
Brand | Crompton Instruments | ||
Country of Manufacture | Italy | ||
MEASURED PARAMETERS | |||
Active Energy (kWh) | Line Power Factor (PF) | ||
Active Power (W) | Line Reactive Power (kVAr) | ||
Apparent Energy (kVAh) | Line to Line Voltage (V) | ||
Apparent Power (VA) | Line to Neutral Voltage (V) | ||
Average Current (I) | Maximum Current (I) | ||
Average Power Demands (W) | Maximum Power Demands (W) | ||
Average Voltage (V) | Maximum Voltage (V) | ||
Current (I) | Power Factor (PF) | ||
Current in Neutral (I) | Reactive Energy (kVArh) | ||
Frequency (Hz) | Reactive Power (VAr) | ||
Hours Run (hr) | Total Harmonic Distortion (Amps) | ||
Line Active Power (W) | Total Harmonic Distortion (Volts) | ||
Line Apparent Power (kVA) | Voltage (V) | ||
Line Current (I) |
Planning a large project or looking to become a regular customer?
Let us know the product or products you require along with quantities, and we'll get in touch with our best price.