Landis + Gyr E350

by: Landis + Gyr

Product Code: TPWLG350

Availability: Next Day 5 Days

Quick overview

The E350 is a direct connect 100 Amp meter manufactured by Landis and Gyr.  This meter has the same range of features as the Landis + Gyr E230 but the modular design enables communication cartridges to be installed for remote reading and interrogation.  This MID approved meter is suitable for billing purposes, and is 1% accurate between 20 and 100 Amps and 2% accurate from 1 to 20 Amps.

The E350 is configured as a dual rate meter for kWh as standard.  In addition, it records Export Energy (kWh), Line Voltage (V), Line Current (I), Absolute Active Energy (kWh), Imported Reactive Energy (kVarh) and Exported Reactive Energy (kVarh).

The E350 is a direct connect 100 Amp meter manufactured by Landis and Gyr.  This meter has the same range of features as the Landis + Gyr E230 but the modular design enables communication cartridges to be installed for remote reading and interrogation.  This MID approved meter is suitable for billing purposes, and is 1% accurate between 20 and 100 Amps and 2% accurate from 1 to 20 Amps.

The E350 is configured as a dual rate meter for kWh as standard.  In addition, it records Export Energy (kWh), Line Voltage (V), Line Current (I), Absolute Active Energy (kWh), Imported Reactive Energy (kVarh) and Exported Reactive Energy (kVarh).

Meter TypeThree Phase
Fitting TypeWall Mounted
Max Current (amps)100
MID ApprovedYes
SmartNo
Input TypeDirect Connect
Output Typen/a (optional comms cartridges available)
TariffsDual
Import / ExportImport & Export
AvailabilityNext Day
ConditionNew
BrandLandis + Gyr
Country of ManufactureSwitzerland
MEASURED PARAMETERS
Active Energy (kWh)Line Power Factor (PF)
Active Power (W)Line Reactive Power (kVAr)
Apparent Energy (kVAh)Line to Line Voltage (V)
Apparent Power (VA)Line to Neutral Voltage (V)
Average Current (I)Maximum Current (I)
Average Power Demands (W)Maximum Power Demands (W)
Average Voltage (V)Maximum Voltage (V)
Current (I)Power Factor (PF)
Current in Neutral (I)Reactive Energy (kVArh)
Frequency (Hz)Reactive Power (VAr)
Hours Run (hr)Total Harmonic Distortion (Amps)
Line Active Power (W)Total Harmonic Distortion (Volts)
Line Apparent Power (kVA)Voltage (V)
Line Current (I)

ADD NEW QUESTION

Name
Email
Question
Are you happy for us to display this question on the website?

Related Products

The item has been added to your basket

Continue Shopping
Proceed To Checkout
Free Delivery For Orders Over £ 50 ex. VAT
Order by 4PM For Next Working Day Delivery
Huge Range In Stock Getting You What You Need, FAST
Expert Advice Speak To One Of Our Friendly Team

REQUEST A QUOTATION

Planning a large project or looking to become a regular customer?
Let us know the product or products you require along with quantities, and we'll get in touch with our best price.