by: Carlo Gavazzi
Product Code: SPDCGEM112
Availability: Enquire Below
The Carlo Gavazzi EM111 is a innovative single phase meter, measuring circuits up to 100A via direct connection. It can be supplied with either Pulse, Modbus or Mbus outputs and is available with or without MID certification, (required if being used for a billing application).
The EM112 is the smallest 100 Amp meter on the market. It is manufactured in the EU by the Italian company Carlo Gavazzi. Remarkably this compact unit displays both import and export energy and can record readings on two separate tariffs. It uses an integrated touch keypad and 8-digit LCD display to navigate through the meter settings.
The EM112 is a reliable class 1 meter displaying Energy (kWh), Active Power (W), Reactive Energy (kVArh), Voltage (V), Current (I), Power Factor (pf), Frequency (Hz), kW demand and kW demand peak.
This meter, when supplied with a Modbus output, is perfectly suited for integration with the Carlo Gavazzi's remote energy management tool, the UWP.
SPW Part Code | Manufacturer Part Code | Description |
SPDCGEM112O | EM112DINAV81XO1X | Pulse Output |
SPDCGEM112S | EM112DINAV81XS1X | Modbus Output |
SPDCGEM112M | EM112DINAV81XM1X | Mbus Output |
SPDCGEM112OP | EM112DINAV81XO1P | Pulse Output & MID |
SPDCGEM112SP | EM112DINAV81XS1P | Modbus Output & MID |
SPDCGEM112MP | EM112DINAV81XM1P | Mbus Output & MID |
Meter Type | Single Phase | ||
Fitting Type | DIN Rail | ||
Max Current (amps) | 100A | ||
MID Approved | Yes / No * | ||
Smart | No | ||
Input Type | Direct Connection | ||
Output Type | Modbus / Mbus / Pulse * | ||
Tariffs | Dual (controlled externally) | ||
Import / Export | Import & Export | ||
Accuracy Class | B (Cl. 1) | ||
Max. Cable Size | 36mm² | ||
Fuse Type (Voltage Reference) | 315mA | ||
Fuse Type (Auxiliary) | n/a | ||
Module Width | 2 | ||
Availability | Special Order | ||
Brand | Carlo Gavazzi | ||
Country of Manufacture | Italy | ||
MEASURED PARAMETERS | |||
Active Energy (kWh) | Line Power Factor (PF) | ||
Active Power (W) | Line Reactive Power (kVAr) | ||
Apparent Energy (kVAh) | Line to Line Voltage (V) | ||
Apparent Power (VA) | Line to Neutral Voltage (V) | ||
Average Current (I) | Maximum Current (I) | ||
Average Power Demands (W) | Maximum Power Demands (W) | ||
Average Voltage (V) | Maximum Voltage (V) | ||
Current (I) | Power Factor (PF) | ||
Current in Neutral (I) | Reactive Energy (kVArh) | ||
Frequency (Hz) | Reactive Power (VAr) | ||
Hours Run (hr) | Total Harmonic Distortion (Amps) | ||
Line Active Power (W) | Total Harmonic Distortion (Volts) | ||
Line Apparent Power (kVA) | Voltage (V) | ||
Line Current (I) | |||
* Dependant on model selected |
Planning a large project or looking to become a regular customer?
Let us know the product or products you require along with quantities, and we'll get in touch with our best price.