ND Metering Solutions - Rail 350

by: ND Metering Solutions

Product Code: TPDND350

Availability: Next Day Special Order

Download Summary Sheet

Quick overview

The Rail 350 is the mid-range three phase DIN Rail meter manufactured by ND Metering Solutions.  It can be supplied with either a 5A or 0.333V input and has a number of optional features including Modbus or Pulse outputs.

FULL PRODUCT SPECIFICATION

Optional Extras

The ND Metering Solutions Rail 350 is manufactured in the UK and come with a 5-year manufacturer's warranty.

This CT operated DIN Rail meter displays individual phase and total Active Power (W); Active Energy (kWh) is recorded to an accuracy better than class 1 and Reactive Energy (kVArh) better than class 2.  It includes a resettable hours run counter (hr) and displays Frequency (Hz) In addition, to measuring Power Factor (pf) for each phase and the sum of all phases.  It also records Live to Live and Live to Neutral Voltage (V) and Current (I) on each phase.

As standard the Rail 350 comes with 2 pulse outputs for kWh and kVArh; both are configurable for both duration and rate. In addition, a Modbus Output model is available

RAIL 350 VARIANTS

SPW Part CodeManufacturer Part CodeDescription
TPDND350R35/5A/230
5A Input with Pulse Output
TPDND350MR35MOD/5A/230
5A Input with Modbus Output
TPDND350VR35/V/230
0.333V Input with Pulse Output
TPDND350VMR35MOD/V/230
0.333V Input with Modbus Output
Meter TypeThree Phase
Fitting TypeDIN Rail
Max Current (amps)5A / 0.333V *
MID ApprovedNo
SmartNo
Input TypeCurrent Transformer
Output TypePulse / Modbus *
TariffsSingle
Import / ExportImport Only
Fuse Type (Voltage Reference)1A Fast Blow
Fuse Type (Auxiliary)0.1A Fast Blow
Module Width6
AvailabilityNext Day
BrandND Metering Solutions
Country of ManufactureUK
MEASURED PARAMETERS
Active Energy (kWh)Line Power Factor (PF)
Active Power (W)Line Reactive Power (kVAr)
Apparent Energy (kVAh)Line to Line Voltage (V)
Apparent Power (VA)Line to Neutral Voltage (V)
Average Current (I)Maximum Current (I)
Average Power Demands (W)Maximum Power Demands (W)
Average Voltage (V)Maximum Voltage (V)
Current (I)Power Factor (PF)
Current in Neutral (I)Reactive Energy (kVArh)
Frequency (Hz)Reactive Power (VAr)
Hours Run (hr)Total Harmonic Distortion (Amps)
Line Active Power (W)Total Harmonic Distortion (Volts)
Line Apparent Power (kVA)Voltage (V)
Line Current (I)

* Dependant on model selected

ADD NEW QUESTION

Name
Email
Question
Are you happy for us to display this question on the website?

PREVIOUS QUESTIONS

Iraj Farazjou

Q: Does Rail350 meter show the "actual" total PF for any load connected to a 3-Phase feed? Does it actually measure the phase shift (angle) between voltage and current of all 3 phases and provide the total actual value of a reactive load? Further, I understand from the manual that PF measurement (< 0.95) would only be useful if the meter will read all 3 voltages (all 3 phases), while "Balance Voltage Mode" is NOT selected. Is my understanding correct?


A: 

Power Factor is recorded over all three phases, so yes this can be for any load connected to it.

It measures the actual phase shift between voltage and current for all 3 phases and provide actual value for active & reactive load.

Yes you need all three voltages to measure the Power Factor.

Kind Regards,

The Stephen P Wales Team

Related Products

The item has been added to your basket

Continue Shopping
Proceed To Checkout
Free Delivery For Orders Over £ 50 ex. VAT
Order by 4PM For Next Working Day Delivery
Huge Range In Stock Getting You What You Need, FAST
Expert Advice Speak To One Of Our Friendly Team

REQUEST A QUOTATION

Planning a large project or looking to become a regular customer?
Let us know the product or products you require along with quantities, and we'll get in touch with our best price.