The EM210 is a 5 Amp, CT operated, three-phase energy meter. This meter is unique in that it can be installed either as a DIN Rail or 72x72mm Panel Mounted meter, making it flexible for installers.

It measures a wealth of parameters including Active Energy (kWh) and Reactive Energy (kVArh), Line to Line and Line to Neutral Voltages (V), Current (I), Power Factor (PF) and Frequency (Hz).  It also measures Active Power (W), Reactive Power (Var) and Apparent Power (kVAh) both for each phase and cumulatively.

This model comes with a single programmable pulse output as standard which can be programmed to produce a pulse anywhere between 0.01 and 9.99 kWh.  The pulse length options are 30ms, 100ms or 120ms. It also has RS485 Modbus communication for remote reading of all of the meter’s data.

This meter is suitable for 3Ph balanced and unbalanced loads as well as single and 2 phase supplies.

SPW Part CodeManufacturer Part CodeDescription
TPDCG21OXEM21072DAV53HOX
Pulse Output
TPDCG21SX
EM21072DAV53HOS
Modbus Output
TPDCG21OP
EM21072DAV53HOXPFBD
Pulse Output, MID & DIN Rail
TPPCG21OP
EM21072DAV53HOXPFBP
Pulse Output, MID & Panel Mount
TPDCG21SP
EM21072DAV53HOSPFBP
Modbus Output, MID & DIN Rail
TPPCG21SP
EM21072DAV53HOSPFBP
Modbus Output, MID & Panel Mount
Meter TypeThree Phase
Fitting TypeDIN Rail
Max Current (amps)5
MID ApprovedYes / No *
SmartNo
Input TypeCurrent Transformer
Output TypePulse / Modbus *
TariffsSingle
Accuracy
B (CL.1)
Import / ExportImport & Export
Fuse Type (Voltage Reference)100 mA
Fuse Type (Auxiliary)Yes
Module Width3
AvailabilityNext Day *


MEASURED PARAMETERS
Active Energy (kWh)Line Power Factor (PF)
Active Power (W)Line Reactive Power (kVAr)
Apparent Energy (kVAh)Line to Line Voltage (V)
Apparent Power (VA)Line to Neutral Voltage (V)
Average Current (I)Maximum Current (I)
Average Power Demands (W)Maximum Power Demands (W)
Average Voltage (V)Maximum Voltage (V)
Current (I)Power Factor (PF)
Current in Neutral (I)Reactive Energy (kVArh)
Frequency (Hz)Reactive Power (VAr)
Hours Run (hr)Total Harmonic Distortion (Amps)
Line Active Power (W)Total Harmonic Distortion (Volts)
Line Apparent Power (kVA)Voltage (V)
Line Current (I)

* Dependant on model selected

ADD NEW QUESTION

Name
Email
Question
Are you happy for us to display this question on the website?

Related Products

The item has been added to your basket

Continue Shopping
Proceed To Checkout
Free Delivery For Orders Over £ 50 ex. VAT
Order by 4PM For Next Working Day Delivery
Huge Range In Stock Getting You What You Need, FAST
Expert Advice Speak To One Of Our Friendly Team

REQUEST A QUOTATION

Planning a large project or looking to become a regular customer?
Let us know the product or products you require along with quantities, and we'll get in touch with our best price.